iorewinnovation.blogg.se

Need to move altium 10
Need to move altium 10









  1. NEED TO MOVE ALTIUM 10 UPDATE
  2. NEED TO MOVE ALTIUM 10 WINDOWS

The Edit Rule Priorities dialog for PCB Rules can now be resized.

NEED TO MOVE ALTIUM 10 UPDATE

PCB Preferences>Board Insight Display page - Font Name and Style now update correctly in DirectX mode Also the speed with which the lists are populated has been improved as well. The Add Selection command no longer selects an extra item in the list. Now the generated directory structure will be zipped into one file that can be added to version control more easily & the. The ODB++ Output generation has been improved. Now the selected layers will be correctly panelized & the generated Gerber files will be loaded in CAMtastic® if auto-load option is turned on. The use of Panelization option when generating Gerber output has been corrected. Gerber files for Mechanical Layers 17 to 32 will now import into PCB through the File>Import menu Now any existing split planes within enclosed polylines will be correctly exported to PCB The Export to PCB command has been improved. The "Set Snap Grid" dialog can now toggle units No fake DRC errors will be generated anymore for available copper area less than 50% from the ideal copper area. Starved Thermals DRC error check has been improved. Problem parsing Spice resistor temperature coefficients was fixed. Selecting and dragging of tabs in a SimView Wave document now works correctly when there are many tabs and the first is not visible. The caption at the top of each page is no longer cropped & the dialog is now no longer sizable so the picture at the top will not disappear anymore. Now the text fields on 1st & last page are no longer editable. Minimum Mask Sliver DRC errors will now be correctly generated for pads rotated 90 or 270 degrees. Only relevant files are opened in CAMtastic® after creating a Testpoint Report from PCBĪltium Designer STEP model functions are no longer affected by a small number of third party STEP viewer applications. Saving a PCB document to ASCII will no longer strip out the embedded board objects The dialog title was also changed to "Placed Components". Now the entries in the components list are no longer truncated to 18 chars. The behaviour of "Jump to Component" dialog has been fixed.

NEED TO MOVE ALTIUM 10 WINDOWS

Mechanical Layers beyond 16 are now displayed in the Update From Libraries comparison listĮxamples folder has been moved out of the Program Files folder to prevent security issues in Vista and Windows 7įixed typo in Messages panel for Testpoint Rule message The memory utilization of Altium Designer has been improved by separating the generation of visual meshes of STEP models into a separate system process. Complete list of Altium Designer updates Date: 24 February 2011











Need to move altium 10